other

SFP+ 16G C17-C61 DWDM 20KM DDM Optical Transceiver


Product Features


  • Supports up to 14.025Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:
  • Standard:  0 to +70°C


Applications


  • 4.25/8.5/14.025G Fibre channel
  • Other Optical links





  • 产品详细信息


RSPD-16GD20-CXX
14.025Gbps SFP+ DWDM Transceiver, Single Mode, 20km Reach




Description


  • The SFP+ transceivers are high performance, cost effective modules supporting data rate of 14.025Gbps and 20km transmission distance with SMF.
  • The transceiver consists of three sections: a Cooled EML laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
  • The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.


Transceiver functional diagram


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4.5

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

-

5

85

%


Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0


+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc



550

mA

Data Rate


4.25

14.025


Gbps


Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

1528.77


1563.86

nm


Spectral Width(-20dB)

Δλ



1

nm


Side-Mode Suppression Ratio

SMSR

30

-


dB


Average Output Power

Pout

-1


+3

dBm

1

Extinction Ratio

ER

8.2



dB


Data Input Swing Differential

VIN

180


850

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω


TX Disable

Disable


2.0


Vcc

V


Enable


0


0.8

V


TX Fault

Fault


2.0


Vcc

V


Normal


0


0.8

V


Receiver

Centre Wavelength

λc

1260


1620

nm


Receiver Sensitivity




-14

dBm

3

Receiver Overload


0.5



dBm

3

LOS De-Assert

LOSD



-15

dBm


LOS Assert

LOSA

-28



dBm


LOS Hysteresis


0.5



dB


Data Output Swing Differential

Vout

300


900

mV

4

LOS

High

2.0


Vcc

V


Low



0.8

V


Notes:

1. The optical power is launched into SMF.

2. PECL input, internally AC-coupled and terminated.

3. Measured with a PRBS 231-1 test pattern @14025Mbps, BER ≤1×10-12.

4. Internally AC-coupled.


Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on



2

ms

Tx Disable Assert Time

t_off



100

µs

Time To Initialize, including Reset of Tx Fault

t_init



300

ms

Tx Fault Assert Time

t_fault



100

µs

Tx Disable To Reset

t_reset

10



µs

LOS Assert Time

t_loss_on



100

µs

LOS De-assert Time

t_loss_off



100

µs

Serial ID Clock Rate

f_serial_clock


100

400

KHz

MOD_DEF (0:2)-High

VH

2


Vcc

V

MOD_DEF (0:2)-Low

VL



0.8

V


Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

 0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 100

mA

±10%

Internal

TX Power

-1 to +3

dBm

±3dB

Internal

RX Power

-16 to -1

dBm

±3dB

Internal


Ordering information

Part Number

Product Description

RSPD-16GD20-C17

SFP+ C17 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C18

SFP+ C18 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C19

SFP+ C19 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C20

SFP+ C20 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C21

SFP+ C21 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C22

SFP+ C22 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C23

SFP+ C23 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C24

SFP+ C24 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C25

SFP+ C25 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C26

SFP+ C26 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C27

SFP+ C27 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C28

SFP+ C28 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C29

SFP+ C29 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C30

SFP+ C30 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C31

SFP+ C31 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C32

SFP+ C32 DWDM, 14.025Gbps, LC, 20km, 0°C~+70C, with DDM

RSPD-16GD20-C33

SFP+ C33 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C34

SFP+ C34 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C35

SFP+ C35 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C36

SFP+ C36 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C37

SFP+ C37 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C38

SFP+ C38 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C39

SFP+ C39 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C40

SFP+ C40 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C41

SFP+ C41 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C42

SFP+ C42 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C43

SFP+ C43 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C44

SFP+ C44 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C45

SFP+ C45 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C46

SFP+ C46 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C47

SFP+ C47 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C48

SFP+ C48 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C49

SFP+ C49 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C50

SFP+ C50 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C51

SFP+ C51 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C52

SFP+ C52 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C53

SFP+ C53 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C54

SFP+ C54 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C55

SFP+ C55 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C56

SFP+ C56 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C57

SFP+ C57 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C58

SFP+ C58 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C59

SFP+ C59 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C60

SFP+ C60 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C61

SFP+ C61 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
100组2选1 100组2选1光切换 光开关 光矩阵设备
具有插入损耗小,切换速度快等特点 RJ45以太网网口通信控制 RS-232串口通信控制 独立控制每个光开关光路
100G QSFP SR4 100G QSFP28 SR4 100m 850nm MPO Optical Transceiver
100G QSFP28 SR4 100m 850nm MPO Optical Transceiver,support 100Gb/s and up to 100m transmission on MM fiber, it works in high-speed IDC connection solutions and so on. Features Compliant with IEEE Std 802.3bm Compliant with SFF-8665 Transmission data rate up to 25 .78125GbpsData rate per channel High Reliability 850nm VCSEL technology Electrically hot-pluggable Single +3 .3V power supply Case temperature range: 0 ~ +70℃ Maximum power consumption 2 .5W Single MPO12 connector RoHS complaint
POB 系列单模4通道并行光收发模块 POB 系列单模4通道并行光收发模块
POB系列单模并行光收发模块主要应用于光背板、服务器与存储器阵列的互连、雷达处理机等甚场景远距 离的高速数据通信连接和并行光互连领域,具有电磁辐射小、抗干扰能力强等特点。模块外形尺寸27mmx27mmx7.8mm,采用10×10Pin LGA连接器,光接口为可插拔的标准MPO连接器接口,工作温度(环境温度)范围为 -40℃~85℃。模块支持单通道传输速率1.25Gbps~10.3125Gbps,传输距离可达10km。
25G SFP28 Transceiver 25G SFP28 CWDM Optical Transceiver
25G SFP28 CWDM optical transceiver module, support 25Gb/s and up to 10 km transmission, it works in high-speed IDC connection solutions, 5G network front-haul solution, and so on.
管理型交换机 2光16电百兆管理型POE交换机 FWPS2016H
16*10/100Mbps RJ45端口+2*千兆Combo端口 FWPS2016H是一款百兆网管型PoE交换机,能满足WIFI AP、IP-camera、WIFI网桥、IP电话等多种类型的设备PoE供电需求。产品采用新一代高性能硬件和软件平台,提供灵活、高性价比的全千兆接入和上行端口,支持三层路由协议、完备的安全防护机制、完善的ACL/QoS策略和丰富的VLAN功能,易于管理维护,满足用户对于网络设备易管理、高安全、低成本的组网需求,适用于校园、酒店及企业园区网络接入、汇聚、核心多种应用场景。
1x8 600UM-900 ~1700nm 机械式光开关器件 1x8 600um光纤 900 ~1700nm 工业级机械式光开关器件 SMA905接头
产品应用 光传输系统中的多路光纤监控 组成光纤及各种光器件的测试系统 多光源/探测器自动换接系统 光传感多点动态监控系统 光测试系统中用于光纤、器件、野外光缆测试 实验室光器件测试研究 组建光纤自愈网络 功能特点 产品具备低损耗、高可靠性 内部器件均选用进口元件,可靠性更好 模块化设计,可灵活嵌入各领域系统 控制方式简单方便易控制 内部电路设计故障自检告知功能
400G QSFP-DD to 4x 100G SFP-DD DAC cable 400G QSFP-DD to 4x 100G SFP-DD DAC Transceiver
Features QSFP-DD Module compliant to QSFP-DD MSA SFP-DD Module compliant to SFP-DD MSA Transmission data rate up to 53. 125Gbps per channel Enable 400Gb/s to 4x100Gb/s Transmission Link length up to 3m Built-in EEPROM functions Operating case temperature 0°C to +70°C RoHS2.0 compliant
10路分光器 1分10 网络分光器
产品特点 属于无源设备,可靠性更高。 模块化设计,1U 机箱可插入2个模块 安装和操作简单,非专业人士即可独立完成。 成本低,集成度高
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系